sst-circle-white-horizontal

Calibration of gas detection systems

Calibration is the process of adjusting and verifying the accuracy of a measuring instrument against a known standard. In the case of fixed gas detectors, calibration is essential to ensure that they provide accurate and reliable readings of the gas concentration in the surrounding environment. Without regular calibration, stationary gas detectors may show erroneous readings, either underestimating or overestimating the presence of harmful gases.

Taratura e calibration

The calibration process

The calibration of fixed gas detectors is a delicate process that requires specialised skills and appropriate instrumentation. It usually involves the following steps:

  • Instrument preparation
  • Comparison with a reference standard
  • Adjustment
  • Verification of accuracy

Before starting the calibration process, it is important to ensure that the instrument is clean and in proper condition, then it is exposed to a known concentration of calibration gas to compare its readings with those of the reference standard. If the readings do not match the expected value, adjustments can be made to align them. After adjustments, the instrument is tested again to ensure that it gives accurate readings.

Taratura e calibration

Calibration frequency

The purpose of the tests is to check the correct functioning of the detectors installed in the field. In European Community countries, gas operation tests and calibration procedures for gas detectors are required by the regulations in force and defined by EN 60079-29-2.

The frequency of maintenance must be defined:

  • by the type of instruments installed in the field
  • by the risk level of the installation area

The guidelines for our gas detectors are:

  • quarterly checks for installations with level 1 emissions (Zone 1)
  • six-monthly verifications for installations with level 2 emissions (Zone 2) or unclassified areas
  • annual verifications for installations in Zone 2 or unclassified area where IR technology detectors are present

Entrust the calibration and periodic maintenance of your gas detection systems to Sensitron​

Our gas detection systems have different maintenance requirements depending on the gases detected and the applications in which they are used. Scheduled maintenance ensures the efficiency of gas detection systems and the resulting safety of workers and environments.

Entrust periodic maintenance to  our team means extending the life cycle of instruments with an impact on both running costs and the environment.

Taratura e calibration

Discover our products

Rilevatore gas, industriale, settore farmaceutico, idrogeno Pharmaceutical Hydrogen

SMART 3G D2

Suitable for detecting flammable substances, toxic gases, refrigerants and oxygen in classified areas.
Certified ATEX, IECEx and SIL2/3

Rilevatore gas, industriale, settore farmaceutico, Pharmaceutical industry

SMART 3G D3

Suitable for detecting in classified areas, Certified ATEX, IECEx and SIL2/3, allows non-intrusive field calibration.

MULTISCAN++ S2 centrale rilevazione gas, industriale, Pharmaceutical industry

MULTISCAN ++S1/++S2

Designed to meet the widest demand from the market, they allow management of up to 264 detectors. ATEX and SIL certified.

Explore our spaces in virtual reality

Within the Sensitron metaverse you can explore application realities reconstructed in virtual reality. Find out more about who we are and what we do, walk inside a production area and learn more about the dangers of gas.


Metaverse, Pharmaceutical industry

Follow us on Linkedin

Follow us on Instagram

Share:

Gli ultimi articoli

Contatti

NEL 2025,
SENSITRON
COMPIE 37 ANNI

Abbiamo celebrato questo risultato, con un nuovo logo: nella stretta di mano vediamo l’impegno preso con i nostri clienti, ma anche la collaborazione, il fare insieme il meglio possibile senza compromessi.

Fondata nel 1988 in provincia di Milano, Sensitron entra a far parte del gruppo Halma plc nel 2021.

This site is registered on wpml.org as a development site. Switch to a production site key to remove this banner.